Customer Background: A Service Company Keeping Contractor Excavators Running
The example customer is a construction machinery service company that maintains excavators for contractors. Machines arrive from site with complaints that range from obvious failures to gradual performance loss, and the workshop has to decide quickly whether a machine needs adjustment, component repair, or a full hydraulic overhaul.
In this case an excavator showed slow hydraulic movements and reduced operating response after the oil warmed up. The symptom was mild when the machine was cold and clear once it reached working temperature, which made it easy to misdiagnose as an operator complaint. The maintenance team needed to investigate the hydraulic system before deciding which components required repair.

Products and Services Used
Our proposed solution uses a portable hydraulic tester configured to measure flow, pressure, and oil temperature. The instrument is brought to the machine, so testing takes place under the conditions that actually produce the fault instead of on a bench far from the jobsite.
Following the machine manufacturer’s procedure, technicians check pump output and take measurements at selected points in the affected circuit. The tester is selected to suit the expected flow, pressure, and flow direction, which keeps the instrument within its working range and the readings trustworthy.
- Flow: shows how much oil the pump actually delivers under load.
- Pressure: shows whether the circuit reaches working and relief values.
- Oil temperature: keeps test conditions comparable between runs.
Readings are compared at defined engine speeds, oil temperatures, and pump control settings. Measuring flow and pressure together can help narrow down the cause of slow or weak hydraulic operation, because a circuit can hold nominal pressure while internal leakage quietly reduces usable flow.
Test Sequence Applied in the Workshop
- Record reported symptoms, excavator model, pump identification and hydraulic schematic.
- Warm the oil to the working temperature stated in the service manual.
- Measure pump output and circuit values at defined engine speeds and pump control settings.
- Repeat the key measurements cold and warm to isolate temperature-related behaviour.
- Compare readings against the manufacturer’s specification and against a healthy circuit where available.
Application Benefits
The testing process helps the maintenance team assess whether pump output meets the specified requirements and decide where further investigation is needed. Instead of removing major components on suspicion, the workshop can point to a measurement that supports the next step.
Comparing measurements before and after warm-up can help investigate temperature-related symptoms. Depending on the results, technicians may carry out additional checks on the pump controls, valves, cylinders, or hydraulic motors. After repair, repeating the checks under comparable conditions provides evidence for evaluating the system’s performance and confirms whether the original complaint has been resolved.
| Test Finding | Likely Direction | Follow-Up Action |
|---|---|---|
| Pump output below specification when warm | Pump wear or internal leakage | Check case drain flow and pump condition |
| Pressure low at defined engine speed | Relief or pump control setting | Verify control settings against the manual |
| Flow and pressure within specification | Downstream valve, cylinder or motor | Test the affected circuit section by section |
Documentation Delivered With the Repair
The service record includes the excavator model, pump identification, hydraulic schematic, reported symptoms, test locations, engine speed, oil temperature, and measured values. Before-and-after readings, inspection findings, and the repair work completed can be included in the maintenance report, giving the contractor a clear record of what was tested, what was found and what was changed.
Why This Matters for Dealers and Service Workshops
For service companies, rental fleets and dealers supporting mixed excavator populations, a portable tester turns a vague “the machine feels slow” complaint into documented evidence. That shortens diagnosis, supports warranty conversations, and helps justify repair decisions to the machine owner.